If you run card payments, you've probably just got through Black Friday, and Cyber Monday is still ahead. So this is a good week for an awkward question. If one of your zones had gone dark at the busiest hour, would the others have coped?
That's where Google's London outage goes next. When europe-west2-b lost power on 20 October, the trouble didn't stay inside that zone. A lot of the damage happened in the two zones that never lost power at all, because everyone tried to move into them at once.
Why this matters
Most multi-zone designs lean on an assumption nobody says out loud. If a zone fails, the work moves across, and the other zones can take it. We draw that as an arrow on the diagram, test it once on a calm afternoon, and tick the box.
The numbers behind that arrow are tighter than they look. Spread evenly over three zones, each one handles a third of your traffic. Lose one, and each survivor has to take half, which is one and a half times its usual load. If your zones normally sit at 70% of capacity at peak, the survivors suddenly need 105%. And that's before anything else has gone wrong.
The usual answer is autoscaling, and most days it's a perfectly good one. But think about what autoscaling needs at that particular moment. The cloud's control plane has to be answering. There has to be spare capacity in the surviving zones and room left in your quotas. Your images have to be reachable. And all of that has to hold while every other customer in the region asks for the same capacity, for the same reason, in the same few minutes.
It's not only your application on the move, either. Database failovers land on the survivors too, along with queued jobs replaying, clients retrying failed requests, and other teams' services doing exactly what yours is doing. The two zones that kept their power then have to absorb all of that at once.
🧭 The shift
From: "If we lose a zone, we fail over to the other two."
To: "If we lose a zone at peak, we know whether the other two can take it, what has to happen first, and how long that takes."
🔍 The lens: the failover headroom test
Get whoever owns capacity planning for your payment path in a room with whoever looks after the cloud account. Ask them to bring your peak numbers. For a lot of teams, this weekend's figures are as good as it gets.
What would the survivors have to carry? Start from peak load, not the average. Work out what each remaining zone, node pool, or data centre would have to handle if one of them disappeared. For three evenly balanced zones, that's one and a half times their normal share. Then compare it with what they can actually handle today, before any scaling happens.
Is that capacity already there, or does it need creating? If it's already running or reserved, great. If it depends on autoscaling or on-demand instances, list everything that has to work for the extra capacity to show up. That means the provider's control-plane APIs, the image registry, your quotas, and spare room in those zones. Note how long scaling takes when it goes smoothly, and what happens to you if it's slow.
What else arrives on the survivors at the same moment? Think of replicas promoting themselves to primary, message consumers rebalancing, retries from customers and partners, and batch jobs starting over. Add any other services sharing the same nodes or clusters. A rough total is fine. You're trying to see whether the pile is bigger than anyone assumed.